Antioch TN Inspections Improper Installed Roof Flashing
December 8, 2009 by Bill Collins
Filed under Inspector Findings
Roof leaks can often be found around the protrusions of a roof such as the electrical mast or plumbing vent stack pipes. It is very important the flashing around these protrusions be properly installed. The roofing shingles should be placed on top of the flashing and extend down both sides to the bottom side of the protruded pipe. The shingles should also be glued with roof cement to the flashing to prevent wind and rain from penetrating under and around the flashing.

TN Home Inspector reveals exposed water pipe
December 6, 2009 by Bill Collins
Filed under Inspector Findings
Water supply line are often found installed in front of a crawlspace vent leaving the supply line exposed to freezing temperatures in winter months. Ultra Sound Inspections recommends the crawlspace vent door be kept closed and possible insulated during the winter months to prevent the pipes from freeze damage.

Exposed Water Supply Line